Liquid scintillation spectrometer - radiometer DPM7001

DPM7001
DPM7001
Show More
Description
Composition
Specification
Application

Products  >>  Spectrometry  >>  Liquid scintillation spectrometer - radiometer DPM7001

Liquid Scintillation Spectrometer - radiometer DPM7001 is designed to measure the activity of beta-emitting radionuclides (H-3, C-14, and others.).  DPM 7001 can be used in all fields of radiation monitoring, in stationary and mobile analytical laboratories, as well as in the nuclear industry companies.

- spectrometer - radiometer DPM7001;
- set of vials 20ml;
- liquid scintillator;

- cabels;

- software and PC.

Spectrometer - radiometer DPM7001 is a device for registering pulses arising from the interaction of beta particles with a liquid scintillator.
The count rate of recorded pulses is proportional to the activity of the measured sample, pulse amplitude is proportional to the energy of the particle that caused them.
On the basis of measurements carried out identification and calculation of activity of beta-emitting radionuclides in samples.

Spectrometer - radiometer DPM7001 consists of the detection unit with two photomultiplier, coincidence circuit, preamplifier, amplifier, amplitude analyzer which
provides spectral analysis of the radiation, and the microprocessor controller.

The signals from the both anodes of the photomultipliers are converted in the coincidence circuit and transmit to the input of the preamplifier, where it is amplified and specially formed for optimal signal / noise ratio and further it is converted into a digital code that is proportional to the absorbed energy.
The resulting data set is stored in the analyzers memory and forms the energy spectrum of the radiation - the dependence of the count of registered pulses of radiation energy.
For further data processing in order to obtain information about the content of radionuclides in the sample of the substance microprocessor controller calculates and displays the results on the screen of the device, or sends them to a PC via the serial interface.

The spectrometer provides a measurement of the energy distribution

of beta radiation within the energy range of:                                         1 – 3500 keV

Range of measured activity of the beta-emitting radionuclides

(U=50%, k=2):                                                                                0,05 – 30000 Bq

Sensitivity for beta radiation of radionuclide H-3 more than:                         37%

Sensitivity for beta radiation of radionuclide C-14 more than:                        94%

Sensitivity for beta radiation of radionuclide Sr-90+Y-90 more than:              99%

The maximum throughput:                                                                      10000 cps

The instability measurements activity within 24 hours of continuous

operation is no more than:                                                                          ±2%

Power supply :                                                                             110 – 240V, 50-60Hz

Weight :                                                                                                    16 kg

Dimensions (WxHxL):                                                                       470x160x430 mm

Operation temperature range  :                                                            +10 .. +40 °C

Relative humidity:                                                                                      <70%

Power consumption:                                                                                   < 40 W