Dosimeter - radiometer MKS-18 is intended to measure:
• ambient dose equivalent rate and Н*(10) and ambient dose equivalent Н*(10) of continuous gamma-radiation;
• ambient dose equivalent rate and Н*(10) and ambient dose equivalent Н*(10) of X-ray and gamma-radiation (including pulse);
• ambient dose equivalent rate Н*(10) and ambient dose equivalent Н*(10) of neutron-radiation;
• flux density of alpha-, beta-, gamma-radiation

Technical characteristics of measuring consoles

Parameters                                                                UIK-9                                UIK-10                          UIK-11

Type of display

OLED

OLED

LCD

Type of case

steel

plastic

plastic

Operating supply voltage, V

3,7

3,7

4,2

Sound alarm

Embedded GPS-sensor (optionally)

Embedded Bluetooth

Power supply

accumulators, >5300 mА·h, (1 pcs)

Li-ion battery, >3100 mА·h, (1 pcs)

accumulators, АА, >1900mА·h, (3 pcs)

Embedded detector BDBG-201-RS

-

-

Degree of protection

IP 67

IP 54

IP 54

Operating temperature range

-40 °С .. +50 °С

-40 °С .. +50 °С

-20 °С .. +50 °С

Dimensions, mm

125×190×86

165×80×50

165×80×50

Weight, kg

1,4

0,4

0,4

Technical and metrological characteristics of gamma detectors

Parameters                                                                                              BDMG-18-RS                            BDBG-201-RS

Type of registered radiation

ADER gamma, FD gamma

ADER gamma, FD gamma

Energy range of registered gamma particles

50 .. 3000 keV

50 .. 3000 keV

Measurement range of ambient dose equivalent rate Н*(10)

0,03-30 μSv/h

0,03-300 μSv/h

Measurement range of ambient dose equivalent Н*(10)

Measurement range of gamma particles flux density, 1/s·sq.cm

3-2400

3-30000

Specific activity Cs-137, Bq/kg

Measurement range of gamma exposure dose rate, μR/h

Measurement range of gamma flux, 1/s

Limits of tolerable intrinsic relative error, %

± 15

± 15

Typical sensitivity, no less

2500 h/s∙μSv

400 h/s∙μSv

Active area of detector

Ø 63 × 63 mm

Ø25 × 40 mm

Type of detector

NaI(Tl)

NaI(Tl)

Protection class

IP 67

IP 54

Operating temperature range

-40 °С .. +50 °С

-40 °С .. +50 °С

Technical and metrological characteristics of beta detectors

Parameters                                                                       BDZB-18-RSF                      BDZB-18b-RS                   BDZB-18s-RS

Type of registered radiation

flux density of β-radiation

flux density of β-radiation

flux density of β-radiation

Energy range of registered beta particles

120 to 3500 keV

50 .. 3000 keV

50 .. 3000 keV

Measurement range of beta particles flux density, 1/min∙sq.cm

1 - 5·10^5

5 - 10000

5 - 10^5

Measurement range of beta surface activity, Bq/sq.cm

0,1-300

0,1-300

0,1-300

Protection class

IP 54

IP 67

IP 54

Operating temperature range

-40 °С .. +50 °С

-40 °С .. +50 °С

-40 °С .. +50 °С

Limits of tolerable intrinsic relative error, %

± (20 + 5/Ах)

± (20 + 5/Ах)

± (20 + 5/Ах)

Active area of detector, sq.sm

28

80

15

Weight, kg

0,9

1,5

0,3

Dimensions, mm

Ø 90 x 130

130 x 180 x 120

Ø 65 x 65

Type of detector

plastic

СBТ-10 - 2 pcs

plastic

Registration efficiency of beta-radiation Sr-90+Y-90, no less

45%

45%

45%

Technical and metrological characteristics of alpha detectors

Parameters                                                                         BDZA-18-RSF                     BDZA-18d-RSF                  BDZA-18t-RS

Type of registered radiation

flux density of α-radiation

flux density of α-radiation

flux density of α-radiation

Energy range of registered alpha particles

4 MeV – 7 MeV

4 MeV – 7 MeV

4 MeV – 7 MeV

Measurement range of alpha particles flux density, 1/min∙sq.cm

1 - 5·10^5

0,1 – 30000

0,1 – 10^6

Measurement range of alpha surface activity, Bq/sq.cm

0,01-3000

0,01-1000

0,01-30000

Protection class

IP 67

IP 67

IP 54

Registration efficiency of alpha-radiation Рu-239, no less

45%

45%

45%

Operating temperature range

-40 °С .. +50 °С

-40 °С .. +50 °С

-40 °С .. +50 °С

Limits of tolerable intrinsic relative error, %

± (20 + 5/Ах)

± (20 + 5/Ах)

± (20 + 5/Ах)

Active area of detector, sq.sm

70

110

5

Weight, kg

1

1,5

0,2

Dimensions, mm

Ø 120 x 140

130 x 180 x 100

Ø 50 x 60

Type of detector

ZnS(Ag)

ZnS(Ag)

semiconductor

Technical and metrological characteristics of neutron detectors

Parameters                                                                                           BDMN-18-RSF                                 BDKN-18-RS

Type of registered radiation

ADER, ADE, FD n

ADER, ADE, FD n

Energy range of registered neutron-radiation

0,025 eV ... 14 MeV

0,025 eV ... 14 MeV

Measurement range of ambient dose equivalent rate Н*(10) of neutron-radiation

0,1 μSv/h-0,1 Sv/h

0,1 μSv/h-0,1 Sv/h

Measurement range of ambient dose equivalent Н*(10) of neutron-radiation

0,1 μSv-10 Sv

0,1 μSv-10 Sv

Measurement range of flux density of neutron-radiation, 1/s∙sq.cm

0,1 ... 1·10^5

0,1 ... 1·10^5

Energy dependence, %

± 40

Operating temperature range

-40 °С .. +50 °С

-40 °С .. +50 °С

Active area of detector, sq.sm

Ø 30 x 5

Ø 18 × 140

Weight, kg

8,3

2,5

Dimensions, mm

240 x 310 x 290

295 x 156 x 100

Type of detector

thermal neutron detector (in polyethylene moderator, ball Ø 240 mm)

slow neutron counter filled with He-3 (in polyethylene moderator, cylinder Ø100 mm)

Protection class

IP 67

IP 67

Features

• consists of a radiation detector (depending on the type of ionization radiation) and one of consoles (at the Customer's choice): UIK-09 (a metal case, a built-in accumulator block), UIK-10 (a plastic case, the built-in accumulator block, OLED-display), UIK-11 (a plastic case, the built-in accumulator block, LCD-display).
• console UIK-09 (at the Customer's choice) can be equipped with an embedded detector BDBG-201-RS, which expands the functionality features;
• automatic detection of a type of connected detector and activation of measurement modes for this type of detector;

• a possibility to select the measurement algorithm and set the threshold setting for each measurement mode;
• the audible and visual alarms about exceeding of the thresholds during measurement process;
• a simplicity and reliability, an ability to equip with additional detector;
• a short time of measurement and fast automatic adaption to change in radiation situation;
• the unique algorithms of search, localization of sources and fields of ionization radiation;
• work in a wide range of temperatures in the field, to carry logs of wells and boreholes;
• a radiation survey of the area with geo-references, stored in the nonvolatile memory of up to 4000 measurement results with possibility of transfer to PC and imposition to electronic maps (additional option);
• an embedded communication module Bluetooth which provides data exchange between the console and the 
detector by the auxiliary device MOB-01 (the additional option).

bottom of page